Posts

How to remove bubbles from suctioning tube?

Image
Suctioning can help maintain and establish the gas exchange, adequate oxygenation, and alveolar ventilation. Suctioning can be performed through an endotracheal tube, a tracheostomy tube, the mouth, or the nose. How to remove bubbles from suctioning tube or refill a suctioning tube?  Refilling a suctioning tube typically involves the following steps: 1. Prepare the equipment : Ensure you have a clean suctioning tube and a container of sterile saline solution. 2. Disconnect the tube: If the suctioning tube is connected to any equipment or devices, disconnect it to make the refilling process easier. 3. Fill the container : Fill a sterile container with the desired amount of saline solution. Ensure the container is clean and free from any contaminants. 4. Attach the tube to the container: Attach the end of the suctioning tube to the container of saline solution. Ensure it is securely attached to prevent leaks. 5. Prime the tube : Hold the suctioning tube and container of saline soluti...

What are types of wound based on level of contamination?

Image
Surgical wound classification is typically based on the level of contamination. The categories include: Centers for Disease Control and Prevention (CDC) surgical wound classification Class I - Clean Uninfected operative wound with no inflammation No entry into the respiratory, alimentary, genital, or urinary tract Primarily closed, and drained with closed drainage (if necessary) Includes operative incisional wounds following blunt trauma if above criteria met. Treatment : Clean and Protect : Rinse with sterile saline or clean water. Apply a sterile dressing. Monitor Healing : Keep an eye on the wound for signs of infection. Prevention : Maintain Sterility : Ensure clean conditions during surgical procedures or when handling wounds. Hygiene Practices : Wash hands thoroughly before and after touching the wound. Class II - Clean-contaminated Entry into respiratory, alimentary, genital, or urinary tract under controlled conditions without unusual contamination Includes operations involving...

How to clean , disinfect and sterilize laparoscopic instruments?

Image
Processing of Laparoscopic Instruments                Glutaraldehyde formulations are the most popular chemical germicides for high-level disinfection of laparoscopic and endoscopic equipment.   Optimal processing of LI involves several steps that reduce the risk of transmitting infection. These are : 1) Dismantling  Dismantle all removable parts for thorough cleaning.  2)Decontamination  The procedure begins in the theatre itself using the nursing staff wiping off visible blood tissue and body fluids in the instruments with a damp sterile sponge. At the conclusion of this all soiled or contaminated instruments should be placed in a container containing a disinfectant solution such as 0.5% chlorine and allowing them to soak for Ten minutes. 3) Precleaning  Following the instruments reach the sterile supplies processing area, which is preferably a controlled environment, a pre-cleaning treatment with an enzymatic meth...

Merit and Demerits of Robotic assisted Surgery

Image
Robotic assisted surgery   allow a surgeon at a console to operate remote-controlled robotic arms, which may facilitate the performance of procedures. These robotic systems are designed to enhance the surgeon's precision, control, and dexterity, offering potential benefits to both the surgeon and the patient. 1. Robotic System: The surgeon operates from a console equipped with a 3D visualization system and manipulates the robotic arms using hand and foot controls. 2. Enhanced Precision : Robotic systems provide enhanced precision by filtering any hand tremors of the surgeon's movements. The robotic arms translate the surgeon's hand movements into smaller, more precise movements, reducing the risk of human error. 3. Minimally Invasive: Robot-assisted surgery is typically performed using minimally invasive techniques, such as laparoscopy or thoracoscopy. Minimally invasive procedures involve smaller incisions compared to traditional open surgery, resulting in reduced scarring...

Batch Dosimeters with their types

Image
Dosimeters A batch dosimeter is a type of radiation dosimeter that is designed to measure the amount of radiation exposure over a specific period , typically over several weeks or months.   Batch dosimeters are often used in occupational settings where workers may be exposed to radiation regularly, such as in nuclear power plants, medical facilities, or research laboratories. They are also relatively inexpensive and easy to use, making them a practical option for many occupational settings. Radiation workers who are issued single badges for monitoring whole-body dose should wear them in the region of the collar with the label facing out. When a lead apron is worn, the dosimeter should be outside the lead apron.  Technologists who work with fluoroscopy may wear two badges , one on the collar outside the lead apron and one at the waist that is under the apron. The two dosimeters should be distinguished by color or icons indicating their specific locations. Personnel who are issu...

PHYSICAL LAYOUT OF THE SURGICAL SUITE

Image
PHYSICAL LAYOUT OF THE SURGICAL SUITE   The physical layout of an operating theater, also known as an operating room, can vary depending on the hospital or surgical facility. Efficient use of the physical facilities is important. The design of the surgical suite offers a challenge to the planning team to optimize efficiency by creating realistic traffic and workflow patterns for patients, visitors, personnel, and supplies. The design also should allow for flexibility and future expansion. Architects consult surgeons, perioperative nurses, and surgical services administrative personnel before designating functional space within the surgical suite. The surgical suite is divided into three geographic areas that are designated by the physical activities performed in each area Unrestricted Area  In the unrestricted surgical area street clothes are permitted. A corridor on the periphery accommodates traffic from outside, including patients. This area is isolated by doors from the m...

Difference between anesthesia machine & ventilation machine

Image
  An   anaesthetic machine   ( British English ) or   anesthesia machine   ( American English ) is a   medical device   receives medical gases (oxygen, nitrous oxide, air) under pressure and  accurately controls the flow of each  gas individually. A gas mixture of  the desired composition at a define  flow rate is created before a known  concentration of an inhalational  agent vapour is added. Gas and  vapor mixtures are continuously  delivered to the common gas outlet  of the machine, as fresh gas flow  (FGF) , and to the breathing system  and patient . Components of anesthesia machine: It consists of  1.Gas supplier 2. Pressure gauges 3. Pressure regulators (reducing  valves) 4. Flowmeters 5. Vaporizers 6. Common gas outlet 7. A variety of other features, e.g.  high-flow oxygen flush, pressure  relief valve and oxygen supply  f ailure alarm and suction  apparatus 8....

What are the types of indicators?

Image
Indicator Devices inserted into packed set and attached to the outside of the wrapper/container to monitor sterilization exposure conditions. Sterilization indicators are tools used to verify the effectiveness of a sterilization process. They are important in ensuring that medical equipment, instruments, and supplies are free from harmful microorganisms, and are safe to use on patients.  There are several types of sterilization indicators, including: 1. Biological Indicator  2. Chemical Indicator 3. Mechanical Indicator Biological indicators (BIs): These are the most accurate type of sterilization indicators and are used to monitor sterilization processes that utilize heat, such as autoclaving. They contain spores of heat-resistant bacteria that are killed when the sterilization process is successful. BIs are often used in healthcare settings to ensure that medical equipment and instruments are properly sterilized.   The biological microorganism used in steam ...